• To classify plastic material as Antistatic, Conductive
or
Insulator
• To optimize the dosage of Antistatic Masterbatches &
Conductive Compounds
• To compare the effectiveness of various types of
Antistatic Masterbatches & Conductive Compounds
• To find the Surface & Volume Conductivity of various
powder & liquid
Surface resistivity meter
We also offer
Antistatic Masterbatches
Conductive Masterbatches
VCIP Masterbatches
to meet special needs of the industries
Specifications
Measurement Range
Measurement Accuracy
Resolution
Repeatability
Open Circuit Voltage
Indication
Test actuation
Power Supply
Calibration
Warranty
Measurement Accuracy
Resolution
Repeatability
Open Circuit Voltage
Indication
Test actuation
Power Supply
Calibration
Warranty
: 103 to 1012 Ohms & Ohms / Sq
: +/- 10%
: ½ Decade
: +/- 10%
: 100 V (+/- 10V)
: Visual by different colour LED’s
: Press to Test switch
: 9 Volts DC Battery
: Calibration recommended once in 12 mths
: 12 months from the Date of Supply
: +/- 10%
: ½ Decade
: +/- 10%
: 100 V (+/- 10V)
: Visual by different colour LED’s
: Press to Test switch
: 9 Volts DC Battery
: Calibration recommended once in 12 mths
: 12 months from the Date of Supply
Static Charge Meter
Specifications
Measurement Range
Measurement Accuracy
Indication
Test actuation
Power Supply
Low Battery
Calibration
Warranty
Measurement Accuracy
Indication
Test actuation
Power Supply
Low Battery
Calibration
Warranty
: +/- 0-10 KV
: +/- 10%
: 2 ½ Digit LCD Display
: Press TO read
: 9 Volt Battery
: Warning at 7.0 Volts
: Recommended every 12 mths
: 12 Months
: +/- 10%
: 2 ½ Digit LCD Display
: Press TO read
: 9 Volt Battery
: Warning at 7.0 Volts
: Recommended every 12 mths
: 12 Months
• To locate the Static Charge present
• To finds the intensity of Static Charges
• To gets the polarity
• To classify material into Antistatic / Insulator
• Non contact type easy to operate & has a range of 0-10 KV
• During mfg. of Antistatic / Conductive plastic films, its very
important to know, when exactly the required Antistatic /
Conductive material has come and when to start winding
operation in the roll form
• To finds the intensity of Static Charges
• To gets the polarity
• To classify material into Antistatic / Insulator
• Non contact type easy to operate & has a range of 0-10 KV
• During mfg. of Antistatic / Conductive plastic films, its very
important to know, when exactly the required Antistatic /
Conductive material has come and when to start winding
operation in the roll form
All conductive and antistatic materials will not generate static voltage on friction, where as all normal plastic generate 5-10
KV friction. Normal plastic have 1012 Ohms and above, and for antistatic and conductive products their values are much
lowers.Conductive properties are obtained generally by using the conductive compounds, which are ready to us.